Ice Flake Machine Capacity 5 Ton / 24 Hours
Description:
Technical Specifications & Support ofMEF 050 .
IceFlake Machine MEF 050 . Flake Ice MachineOperating Conditions
Capacity:5 Tons/24 hours
Cooling/evaporatingtemperature : -20° C
Condensingtemperature : 40°C
Machine operating system:
FullAutomatic Control
Automaticharvest (production)
Refrigerant: Freon R404 A / R22
Iceflake thickness: 1.8 mm to 2 mm
Thetotal dimensions of the flake(est) ice machine: W x W x H = 2,500 x 2,000 x 1,750 mm
Flake Ice Machine Technical Specifications(MEF 050):
FlakeIce Evaporator:
DrumEvaporator Material: SUS Plate 304
Rollerblade drive : Gear motor 1 HP (750 W)/380V/3 phase
CirculationPump raw material: 1 HP (750 W)/220V/1 phase
Notes:
background:#F8F9FA">- Prices in Hundreds of Millions (DP Prices Only)
- Thegoods are made first (if there are ready, must see the goods in the workshop first). - Prices do not include postage (postagelisted is for sending purchase documents)-Preferably chat to the number listed in the picture of the item - A visit to the workshop is required beforemaking a transaction. (Due to the large value).- Theprice listed is only for the unit of goods (not including installation costs for technicians, accommodation and transportation for installation technicians)Ice Flake Raw Material Tank &Distribution Ice Flake :
Tanktype: Rectangular tank (box tank)
Tankvolume (estimated): 300 Kg
TankMaterial: SUS 201 / 304 plate thickness 1.5 mm
Tankinsulator: aeroflex 20 mm
FlakeIce Machine Piping & Fitting System :
Refrigerantpiping : ASTM B 280 . seamless copper pipe
Insulatorrefrigerant pipe: aeroflex 40 mm
Ice flake Machine Construction:
Underconstruction & structure : UNP carbon steel finish paint.
Construction& superstructure : UNP carbon steel finish paint
Flake Ice Machine Utility
Watersources are needed to meet water needs for the process of raw material for ice flakes and sanitation for factory hygiene
Rawmaterial water needs: 5 m3/day (5,000 liters/24 hours).
Iceflake raw material reservoir tank (raw material water reservoir)
Electricity
Electricityis needed to drive the motor, pump and electrical system of the flake ice machine
Electricityrequirement of flake ice machine;
Compressor1 stage: 23 HP (17.250 Watt / 380V / 3 phase)
Gearmotor ice cutter: 1 HP (750 Watt / 380V / 3 phase)
Watercirculation pump: 1 HP (750 Watt / 380 V / 3 phase)
CoolingTower Pump : 1 HP(750 Watt/220 V/1 phase)
MotorCooling Tower : HP (375 Watt / 380 V / 3 phase) 1.2.2.1.6.
Totalelectricity demand: 19,875 Watt / 380 V / 3 phase
Minimuminstalled power: 33 Kva / 380 V / 3 phase