Air Blast Freezer capacity 0.6 Ton
Description:
1.1. Technical Specifications & AirBlast Freezer Support
1.1.1. Air Blast Freezer (ABF)
Air blast freezer is a refrigeration unitdesigned for a functioning freezing process prosesas follows :
- Prevents reduced fluid content
- Prevents discoloration and taste Preventsthe proliferation of freezing bacteriafast.
- The initial temperature of the material +30 C is frozen to a temperature of -38 ° C within 8 hours
1.1.1.1. Dimensions of the room (Outside):W x W x H = 2,300 x 1,700 x 2,300 mm
1.1.1.2. Capacity : 0.6 ton
1.1.1.3. Blast time: 8 hours
1.1.1.4. Refigerant : Freon R404 or R22
1.1.1.5. Room temperature : -38 to -45°C
1.1.1.6. Lighting system: water proof TLlamp
1.1.1.7. Automatic control
1.1.1.8. Air blast freezer cooling airsystem:
1.1.1.8.1. Compressor type semi hermetic 2 stage
1.1.1.8.2.Air cooler evaporator
1.1.1.8.3. Air cooler condenser
1.1.1.9. Construction of air blast freezerroom:
1.1.1.9.1. Wall & roof construction : Sandwich Panel PPGI G300 Z275 0.5 mm off - white
1.1.1.9.2. Floor construction : Sandwich panel PPGI G300 Z275 0.5 mm + Aluminum bordes 2 mm
1.1.1.9.3. Insulator: 150 mm thick polyurethane foam (density 45 kg/m3)
1.1.1.9.4. Knock down system with cam-lock lock (iron & plastic)
1.1.1.9.5. Swing door with Heavy duty Hinge & safety lock system
1.1.1.9.6. Door size: 1000 mm x 2000 mm
1.1.1.9.7. Plastic curtain over lapping 20% of the door size.
1.1.1.10. Electrical:
1.1.1.10.1 Compressor 2 stage : 5 HP (3,750 Watt) / 380 V / 3 Phase
1.1.1.10.2 Evaporator Fan & Heater : (2x375 watts) + 500 watts / 380 V / 3 Phase
1.1.1.10.3 Condenser Fan : 375 watt / 380 V / 3 Phase
1.1.1.10.4 Total electricity demand (estimated): 5,375 watts / 380 V / 3 Phase
2.1. Utilities / Support Air Blast FreezerRoom (*Provided by Buyer)
2.1.1. Building / Civil Construction
Building/civil construction needed to putair blast freezer room and supporting machinescooler compressor
2.1.1.1 Required area of air blast freezer room : W x W X H = 3,000 x 2,000 x 3,000 mm
2.1.1.2 Refrigeration unit area requirement Wx W x H : 2,000 x 3,000 x 3000 mm
2.1.2. Electricity
Electricity is needed to drive motors,compressors and electrical systems in cold storage
2.1.2.1Electricity requirement for air blast freezer room (estimated): 5,375 KW/380V/3 phase