sql

VESTREF MEF 050 Ice Flake Machine Capacity 5 Ton / 24 Hours

Rp. 497,500,000
Last Updated
21 Sep 2021
Minimum Order
1 unit

Specification of VESTREF MEF 050 Ice Flake Machine Capacity 5 Ton / 24 Hours

Ice Flake Machine Capacity 5 Ton / 24 Hours

Description :

 

Technical Specifications & Support of MEF 050 .

Ice Flake Machine MEF 050 . Flake Ice Machine Operating Conditions

Capacity: 5 Tons/24 hours

Cooling/evaporating temperature : -20° C

Condensing temperature : 40°C

 

Machine operating system:

Full Automatic Control

Automatic harvest (production)

Refrigerant : Freon R404 A / R22


Ice flake thickness: 1.8 mm to 2 mm

The total dimensions of the flake(est) ice machine: W x W x H = 2,500 x 2,000 x 1,750 mm


Flake Ice Machine Technical Specifications (MEF 050):

Flake Ice Evaporator:

Drum Evaporator Material: SUS Plate 304

Roller blade drive : Gear motor 1 HP (750 W)/380V/3 phase

Circulation Pump raw material: 1 HP (750 W)/220V/1 phase

 

Ice Flake Raw Material Tank & Distribution Ice Flake :

Tank type: Rectangular tank (box tank)

Tank volume (estimated): 300 Kg

Tank Material: SUS 201 / 304 plate thickness 1.5 mm

 

Tank insulator: aeroflex 20 mm

Flake Ice Machine Piping & Fitting System :

Refrigerant piping : ASTM B 280 . seamless copper pipe

Insulator refrigerant pipe: aeroflex 40 mm

 

Ice flake Machine Construction:

Under construction & structure : UNP carbon steel finish paint.

Construction & superstructure : UNP carbon steel finish paint

 

Flake Ice Machine Utility

Water sources are needed to meet water needs for the process of raw material for ice flakes and sanitation for factory hygiene

Raw material water needs: 5 m3/day (5,000 liters/24 hours).

Ice flake raw material reservoir tank (raw material water reservoir)

 

Electricity

Electricity is needed to drive the motor, pump and electrical system of the flake ice machine

Electricity requirement of flake ice machine;

Compressor 1 stage: 23 HP (17.250 Watt / 380V / 3 phase)

Gear motor ice cutter: 1 HP (750 Watt / 380V / 3 phase)

Water circulation pump: 1 HP (750 Watt / 380 V / 3 phase)

Cooling Tower Pump : 1 HP(750 Watt/220 V/1 phase)

Motor Cooling Tower : HP (375 Watt / 380 V / 3 phase) 1.2.2.1.6.

Total electricity demand: 19,875 Watt / 380 V / 3 phase

Minimum installed power: 33 Kva / 380 V / 3 phase

 